TRAINING MEDIUM VOLTAGE (POWER CIRCUIT BREAKERS & SWITCHGEAR)
TRAINING TEGANGAN MENENGAH
TRAINING CIRCUIT BREAKER UTILI SATION
TRAINING MEDIUM VOLTAGE
DESCRIPTION
Switchgear (and circuit breakers) are obviously critical components in electrical distribution systems and their operation significantly affects the overall operation of the system. The workshop will discuss application, installation, maintenance and testing issues relating to medium and high voltage switchgear and circuit breakers. There will also be a coverage of low voltage switchgear. You will receive a thorough grounding in switchgear theory and standards. You will gain a solid understanding of the issues associated with the proper application, installation and maintenance of these critical items of equipment with an overriding emphasis on safety. This comprehensive and practical workshop emphasises medium voltage switchgear which represents most of the switchgear installed on electrical distribution systems. The focus here is on air blast, oil, SF6 and vacuum circuit breakers. Case studies covering the main manufacturer’s equipment will illustrate the important practical
principles. Other power system protection components will be discussed as well to ensure that switchgear is understood in the correct context.
OUTLINE
- SWITCHGEAR – ORIGINS & TYPES
* Single line diagrams
* Active and passive network components
* Circuit breaker utili sation
* Alternative forms of MV switchgear – ring main units, load breaking/fault making switches,
* Fuse switches
* HV fuses in combination with, and as alternative to circuit breakers
* Auto-reclosers and auto-reclose operation - APPLICATION OF SWITCHGEAR
* Principles of current interruption
* Plain break circuit breakers
* Bulk and small oil volume circuit breakers
* Turbulator (explosion pot)
* Operating mechanisms
* Transfer earth circuit breakers
* Air break and air blast switchgear
* SF6 and Vacuum
* Switchgear in association with disconnectors
* Fixed and withdrawable designs
* Switchgear standards
* Factors affecting switchgear selection - SPECIFICATION OF SWITCHGEAR
* Switchgear rating – highest system and impulse withstand voltages, load and short circuit currents
* Simple and complex protection systems
* Switchgear ancillaries, measurement CTs, VTs, relays
* Cable terminations
* Indoor and outdoor operation
* Substation and switch room layouts and design - SHORT CIRCUIT TESTING
* Symmetrical and asymmetrical breaking
* Make and break operations
* Understanding test oscillograms - SAFETY POLICIES
OPERATION OF MODERN SWITCHGEAR
ASSET MANAGEMENT IN A SWITCHGEAR CONTEXT
DIAGNOSTICS, TESTING & MAINTENANCE
* Switchgear inspection methodologies
* Partial discharge measurement and survey
* Timing tests
* Thermovision
* Mechanisms of deterioration
* Principles of circuit breaker maintenance
* Maintaining oil circuit breakers
* Contact maintenance and contact wipe
* Oil testing
* Maintaining vacuum circuit breakers
* Maintaining SF6 circuit breakers
* SOPs and DINs
* Switchgear defects and defect control systems - STUDY CASE
OBJECTIVES :
- Selection of appropriate type and rating of circuit breakers and switchgear
- Fundamentals of operation of switchgear
- Switchgear components (CTs, VTs, relays, cable terminations)
- Safe operational policies including safety rules and safety documents
- Diagnostic tools and test equipment
- Safe maintenance policies including safe working in switch rooms, indoor and outdoor substations
Jadwal pelatihan trainingmekatronika.com tahun 2023 :
- Batch 1 : 11 – 12 Januari 2023 | 25 – 26 Januari 2023
- Batch 2 : 01 – 02 Februari 2023 | 15 – 16 Februari 2023
- Batch 3 : 01 – 02 Maret 2023 | 15 – 16 Maret 2023
- Batch 4 : 04 – 05 April 2023 | 11 – 12 April 2023
- Batch 5 : 10 – 11 Mei 2023 | 24 – 25 Mei 2023
- Batch 6 : 07 – 08 Juni 2023 | 21 – 22 Juni 2023
- Batch 7 : 12 – 13 Juli 2023 | 26 – 27 Juli 2023
- Batch 8 : 09 – 10 Agustus 2023 |23 – 24 Agustus 2023
- Batch 9 : 06 – 07 September 2023 | 20 – 21 September 2023
- Batch 10 : 04 – 05 Oktober 2023 | 18 – 19 Oktober 2023
- Batch 11 :01 – 02 November 2023 | 15 – 16 November 2023
- Batch 12 : 05 – 06 Desember 2023 | 12 – 13 Desember 2023
Catatan : Jadwal tersebut dapat disesuaikan dengan kebutuhan calon peserta training Penerapan Switchgear pasti jalan
Invetasi dan Lokasi pelatihan Circuit breaker utili sation di bali :
· Yogyakarta, Hotel 101 (6.500.000 IDR / participant)
· Jakarta, Hotel Amaris Kemang (6.500.000 IDR / participant)
· Bandung, Hotel Neo Dipatiukur (6.500.000 IDR / participant)
· Bali, Hotel Ibis Kuta(7.500.000 IDR / participant)
· Surabaya, Hotel Amaris, Ibis Style (6.000.000 IDR / participant)
· Lombok, Sentosa Resort (7.500.000 IDR / participant)
Catatan : Apabila perusahaan membutuhkan paket in house training, anggaran investasi pelatihan dapat menyesuaikan dengan anggaran perusahaan.
Fasilitas pelatihan Penerapan Switchgear di bali :
- FREE Airport pickup service (Gratis Antar jemput Hotel/Bandara/Stasiun/Terminal)
- FREE Akomodasi ke tempat pelatihan bagi peserta training Circuit breaker utili sation bali pasti running
- Module / Handout training Tegangan menengah bali fixed running
- FREE Flashdisk
- Sertifikat training Medium voltage (power Circuit Breakers & Switchgear) di bali murah
- FREE Bag or bagpackers (Tas Training)
- Training Kit (Dokumentasi photo, Blocknote, ATK, etc)
- 2xCoffe Break & 1 Lunch, Dinner
- FREE Souvenir Exclusive
- Training room full AC and Multimedia
.