DESCRIPTION

          Switchgear (and circuit breakers) are obviously critical components in electrical distribution systems and their operation significantly affects the overall operation of the system. The workshop will discuss application, installation, maintenance and testing issues relating to medium and high voltage switchgear and circuit breakers. There will also be a coverage of low voltage switchgear. You will receive a thorough grounding in switchgear theory and standards. You will gain a solid understanding of the issues associated with the proper application, installation and maintenance of these critical items of equipment with an overriding emphasis on safety. This comprehensive and practical workshop emphasises medium voltage switchgear which represents most of the switchgear installed on electrical distribution systems. The focus here is on air blast, oil, SF6 and vacuum circuit breakers. Case studies covering the main manufacturer’s equipment will illustrate the important practical
principles. Other power system protection components will be discussed as well to ensure that switchgear is understood in the correct context.

OUTLINE

SWITCHGEAR – ORIGINS & TYPES
   * Single line diagrams
   * Active and passive network components
   * Circuit breaker utili sation
   * Alternative forms of MV switchgear – ring main units, load breaking/fault making switches,
   * Fuse switches
   * HV fuses in combination with, and as alternative to circuit breakers
   * Auto-reclosers and auto-reclose operation

APPLICATION OF SWITCHGEAR
   * Principles of current interruption
   * Plain break circuit breakers
   * Bulk and small oil volume circuit breakers
   * Turbulator (explosion pot)
   * Operating mechanisms
   * Transfer earth circuit breakers
   * Air break and air blast switchgear
   * SF6 and Vacuum
   * Switchgear in association with disconnectors
   * Fixed and withdrawable designs
   * Switchgear standards
   * Factors affecting switchgear selection

SPECIFICATION OF SWITCHGEAR
   * Switchgear rating – highest system and impulse withstand voltages, load and short circuit currents
   * Simple and complex protection systems
   * Switchgear ancillaries, measurement CTs, VTs, relays
   * Cable terminations
   * Indoor and outdoor operation
   * Substation and switch room layouts and design

SHORT CIRCUIT TESTING
   * Symmetrical and asymmetrical breaking
   * Make and break operations
   * Understanding test oscillograms

SAFETY POLICIES
OPERATION OF MODERN SWITCHGEAR
ASSET MANAGEMENT IN A SWITCHGEAR CONTEXT
DIAGNOSTICS, TESTING & MAINTENANCE
   * Switchgear inspection methodologies
   * Partial discharge measurement and survey
   * Timing tests
   * Thermovision
   * Mechanisms of deterioration
   * Principles of circuit breaker maintenance
   * Maintaining oil circuit breakers
   * Contact maintenance and contact wipe
   * Oil testing
   * Maintaining vacuum circuit breakers
   * Maintaining SF6 circuit breakers
   * SOPs and DINs
   * Switchgear defects and defect control systems

STUDY CASE

OBJECTIVES :
   *     Selection of appropriate type and rating of circuit breakers and switchgear
   *     Fundamentals of operation of switchgear
   *     Switchgear components (CTs, VTs, relays, cable terminations)
   *     Safe operational policies including safety rules and safety documents
   *     Diagnostic tools and test equipment
   *     Safe maintenance policies including safe working in switch rooms, indoor and outdoor substations

Jadwal pelatihan Tegangan menengah di bandung :

· 2 – 4 Januari 2019

· 6 – 8 Februari 2019

· 4 – 6 Maret 2019

· 1 – 4 April 2019

· 16 – 18 April 2019

· 2 – 4 Me 2019

· 27 – 29 Mei 2019

· 25 – 27 Juni 2019

· 23 – 25 Juli 2019

· 19 – 21 Agustus 2019

· 24 – 26 September 2019

· 22 – 24 Oktober 2019

· 11 – 13 November 2019

· 18 – 20 Desember 2019

Catatan : Jadwal tersebut dapat disesuaikan dengan kebutuhan calon peserta training Penerapan Switchgear pasti jalan

Invetasi dan Lokasi pelatihan Circuit breaker utili sation di bandung :

· Yogyakarta, Hotel 101 (6.500.000 IDR / participant)

· Jakarta, Hotel Amaris Kemang (6.500.000 IDR / participant)

· Bandung, Hotel Neo Dipatiukur (6.500.000 IDR / participant)

· Bali, Hotel Ibis Kuta(7.500.000 IDR / participant)

· Surabaya, Hotel Amaris, Ibis Style (6.000.000 IDR / participant)

· Lombok, Sentosa Resort (7.500.000 IDR / participant)

Catatan : Apabila perusahaan membutuhkan paket in house training, anggaran investasi pelatihan dapat menyesuaikan dengan anggaran perusahaan.

Fasilitas  pelatihan Penerapan Switchgear di bandung :

  • FREE Airport pickup service (Gratis Antar jemput Hotel/Bandara/Stasiun/Terminal)
  • FREE Akomodasi ke tempat pelatihan bagi peserta training Circuit breaker utili sation bandung pasti running
  • Module / Handout training Tegangan menengah bandung fixed running
  • FREE Flashdisk
  • Sertifikat training Medium voltage (power Circuit Breakers & Switchgear) di bandung murah
  • FREE Bag or bagpackers (Tas Training)
  • Training Kit (Dokumentasi photo, Blocknote, ATK, etc)
  • 2xCoffe Break & 1 Lunch, Dinner
  • FREE Souvenir Exclusive
  • Training room full AC and Multimedia

.